DataExplorer - Summary
This project is not part of the GNU Project.
The DataExplorer is free software, please see http://www.gnu.org/philosophy/free-sw.html. It is also available at no cost, but without any warranty. Since the implementation is based on Java using the free available libraries RXTXcomm and SWT the execution of this program is possible under a number of popular operating systems like 32/64 Bit GNU/Linux and MS Windows and Mac OS. To execute the only prerequisite is an installed Java runtime with version 1.6 or higher, like IcedTea. The DataExplorer supports national languages where English and German are actually available.
The DataExplorer gathers data from connected devices and display this data for a various of further analysis.
Actual the following devices are available as plug-in:
- AkkuMasterC4 (H-Tronic) - 4 outlet battery charger/discharger
- Akkumatik (Estner) - battery charger/discharger
- 4D-AkkuMonitor (4D Control) - battery data logger
- AV4ms (Fritz Mössinger/accu-select) 4 outlet battery charger/discharger firmware >= 762
- CellLog 8S, (Junsi) battery cell monitor
- CSV2SerialAdapter, import of configurable CVS data files
- DataVario, DataVarioDuo (WStech) variometer, GPS, multi measurement device
- eStation BC6, BC6 80W(dx), BC610, BC8, 902 (Bantam) charger/discharger
- FlightRecorder (Multiplex) Logger
- Futaba-Telemetry (Robbe/Futaba) multi logger device
- GigaLogger (Simprop) multi logger device
- GPS-Logger, GPS-Logger2 (SM-Modellbau) - GPS, multi measurement device
- GPXAdapter GPS Exchange Format file analyzer, extensions prepared for Mikrokopter
- Herkules III Telemetry (Andreas Baier) Multi copter ESC with logging
- HoTTAdapter (Graupner) Receiver-, Vario-, GPS-, GAM-, EAM-, ESC-sensor moduls
- IGCAdapter (OnLine Contest/International Gliding Commission) file analyzer
- iCharger 206B, 208B, 306B, 3010B (Junsi) charger/discharger
- IISI Cockpit V2 (Matthias Isler) telemetry logger
- iMax B6 (SkyRC) charger/discharger
- JetiAdapter (Jeti, Jeti-Box) multi-sensor-log
- JLog2 (SM-Modellbau) - Kontronik Jive motor driver logger
- Kosmik (Kontronik) - motor driver with internal logger
- LinkVario, LinkVarioDuo (WStech) variometer, GPS, multi measurement device
- LiPoWatch (SM-Modellbau) - LiPo saver, cell voltage measurement
- MC3000 (SkyRC) single cell analyzer charger/discharger
- NMEA-Adapter (diverse) - GPS track analyzer
- OpenTx-Telemetry - telemetry data analysis
- Pichler P6 50W, P6 80W, P60 (Pichler) and other eStation BC6 clones charger/discharger
- Picolario, Picolario2 (Renschler) - variometer
- Polaron AC/DC Sports, Pro, EX (Graupner/SJ) - charger/discharger
- QC-Copter/QuadroControl (tt-tronix) control unit
- Simulator test plug-in
- Ultramat12 (Graupner) charger/discharger
- Ultramat16 (Graupner) charger/discharger
- Ultramat16S (Graupner) charger/discharger
- Ultramat18 (Graupner) charger/discharger
- UltraDuoPlus 40 (Graupner) charger/discharger
- UltraDuoPlus 45 (Graupner) charger/discharger
- UltraDuoPlus 50 (Graupner) charger/discharger
- UltraDuoPlus 60 (Graupner) charger/discharger
- UltraDuoPlus 80 (Graupner) charger/discharger
- UltraTrioPlus 14 (Graupner) charger/discharger
- UltraTrioPlus 16S (Graupner) charger/discharger
- UniLog, UniLog2 (SM-Modellbau) multi - measurement device
- VC820, VC840 (Conrad/VoltCraft) multimeter
- Weatronic-Telemetry (Weatronic) - telemetry data analysis
More device are under construction. Help doing this is very welcome.
A device API (IDevice) is defined to enable a relative simple adaptation of a new device to work together with the base application.
Documentation how to proceed doing this is under construction.
Registration Date: Mon May 10 18:24:45 2010
License: GNU General Public License v3 or later
Development Status: 5 - Production/Stable
posted by brueg, Wed Oct 5 18:23:28 2016 - 0 replies
1) remove the restriction re-naming compressed OSD-Files
2) exchange the default value of data file path to user.home instead of using root which causing permission errors
3) MC3000
- fix setting slot programs with capabilities of FW >= 1.12
...
[Read more]
posted by brueg, Sun Sep 11 17:59:58 2016 - 0 replies
1) correct statistics calculation in regard of using max or average calculated using measurement reference ordinal
2) add some error handling if device XML is corrupt in <DataBlock/>
3) enable CSV export using UTF-8 encoding (HoTTAdapterM2 for DashWare)
...
[Read more]
posted by brueg, Sat May 7 06:36:05 2016 - 0 replies
News of this version are:
1) fix - Linux adaptation for incompatible but working SWT SashForm.setWeights
2) MC3000
- add warning message selecting continuous data recording in combination with reduced without pause,..
- add capability to data capture finish for 15 minutes
...
[Read more]
posted by brueg, Sun Mar 6 17:50:18 2016 - 0 replies
1) SkyRC MC3000
- fix gatherer timing problem
- set activation wait timer 60 minutes
- add start stop message
- fix pause reduction in combi record set
2) eStation BC6
- fix missing Balance while loading data from file
3) adapt font used by MAC OS X 10.11
...
[Read more]
[Submit News]